Sample door & hardware schedule featuring Hager and Rixson components...
Document Share
Document Tags
Document Transcript
  08   11   15 Hollow Metal Doors  Master Schedule  08   71   00 Door Hardware  Master Schedule  PROJECT Sawyer Manor General Improvements  940 Caldwell PlColumbus OH 43203(614) 421-6100Capital ImprovementsFax 421-8012Columbus Metropolitan Housing Authority880 E Eleventh AveColumbus OH 43211-2771  ARCHITECT eS Architecture and Development  (614) 764-11156077 Frantz Rd – Suite #201Fax 764-1116Dublin OH 43017  CONTRACTOR Gutknecht Construction Co  (614) 532-54102280 Citygate DrFax 532-5415Columbus OH 43219 10/26/09 CMHA Sawyer Manor Improvements 91026.pdf  1/5 [ less cut sheets ]   2828 W Riverview Ave (937) 278-0706 PhoneDayton OH 45402 (937) 278-7604 Faxprepared by Mark Susey msusey@donet.com CONSOLIDATED M I L L W O R K S U P P L Y  Set: 1.0 Clarify keyway & keying… 32 DoorsExterior to  Unit  ↳↳↳↳  3 0 6 8 Existing OpeningHM6P door 1 3 / 4 ” Existing frameQty Mfgr Description Model Finish1 eaTHEEmbossed 24ga doorTS210 6-panel design  6003 eaTHENon-template hingesRC58   4” x   4”  Therma-Tru proprietary  6521 eaHAGPassage leverset3610-WTN-Tee6261 eaHAGStandard deadbolt3215IC6261 eaHAGADA saddle threshold413S frame opening width  7191 eaHAGDoor sweep750SN width of door  6281 eaHAGWeather seals890SN door/frame perimeter  719 The specified hinges are not compatible for replacement door installation for each…Door width and hardware prep and location details are in the data sheets… Clarify if incompatible with existing conditions for each… Set: 2.0 200 DoorsExterior to  Unit  ↳↳↳↳  3 0 6 8 Existing OpeningExisting door Existing frameQty Mfgr Description Model Finish1 eaHAGDoor sweep750SN width of door  6281 eaHAGWeather seals890SN door/frame perimeter  719   Clarify if incompatible with existing conditions for each… 10/26/09 CMHA Sawyer Manor Improvements 91026.pdf  2/5 [ less cut sheets ] 2828 W Riverview Ave (937) 278-0706 PhoneDayton OH 45402 (937) 278-7604 Faxprepared by Mark Susey msusey@donet.com CONSOLIDATED M I L L W O R K S U P P L Y  Set: 3.0 Clarify keyway & keying… 52 DoorsExterior from  Attic  ↳↳↳↳  3 0 3 0 Access OpeningVented panel Clad rough framingQty Mfgr Description Model Finish2 eaHAGTemplate hingesEC1101 4 1 / 2 ” x   4 1 / 2 ”6302 eaHAGSpring roller latches14456261 eaHAGStandard deadbolt3215IC6261 eaHAGBar pull3E6301 eaRIXOverhead stop   +   hold55-326689 Atypical opening configuration for each as depicted in the plans: 1)Surface hardware installations must be adapted for the rabbet voids…2)Hinges are not ideally suited for installation as detailed…3)Deadbolt prep will compromise the 2x4 framing…   Clarify if incompatible with existing conditions for each… Scheduling Advisory and Procurement Terms IMPORTANT  Unless otherwise noted: (1) each opening is accurately compiled with regard to the project planning as quoted; (2) “minimum” and “maximum” references are identified without regard for aesthetics; and (3) protection plates are for mounting “push” side.Ancillary information MUST be validated, and subordinate attributes – such as latch function or trim design or material finish – will be regarded fully accurate as detailed if not formally revised prior to initializing production or procurement…Project analysis and scheduling is non-refundable and invoiced at 3% of the scoped value plus $200.00. Prior to initializing either production or procurement – or prior to implementing a change to one or the other – formal approval MUST be provided with an indemnification recap. ONCE PRODUCTION, PROCUREMENT OR A CHANGE IS INITIATED, COMPONENTS CAN BE NEITHER CANCELED NOR RETURNED… 10/26/09 CMHA Sawyer Manor Improvements 91026.pdf  3/5 [ less cut sheets ] 2828 W Riverview Ave (937) 278-0706 PhoneDayton OH 45402 (937) 278-7604 Faxprepared by Mark Susey msusey@donet.com CONSOLIDATED M I L L W O R K S U P P L Y  A   N   S   I / B   H   M   A   Base Material & Finish References …by schedule annotation  ANSI US… Finish Description Base Material Related similar   600 PPrimedSteel67462626DSatin chromium platedBrass/Bronze630 652 628 689  62828Satin, clear anodizedAluminum68963032DSatin stainless steelStainless 300626 652 628 689  65226DSatin chromium platedSteel626 630 628 689  689Paint/coated to match 628Any628719 Mill or naturalAluminum 628 689  Door and Frame References …by schedule annotation  Annotation Type DescriptionHM…DoorHollow Metal…6PDoorSix Panel embossed design… 10/26/09 CMHA Sawyer Manor Improvements 91026.pdf  4/5 [ less cut sheets ]   2828 W Riverview Ave (937) 278-0706 PhoneDayton OH 45402 (937) 278-7604 Faxprepared by Mark Susey msusey@donet.com CONSOLIDATED M I L L W O R K S U P P L Y
Search Related
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks